A few months back I wrote about why the factory floor feels unsecurable: uptime pressure that deprioritizes security, equipment that can’t be patched on a normal schedule, and networks flat enough that one compromised sensor can reach almost anything else on them (Securing the Unsecurable: OT, IoT, and the Factory Floor)). The most common question back was some version of: okay, so how do we actually do this?Before the how, here are the principles. They hold regardless of what’s enforcing them.If you’ve sat through a plant security review recently, there’s a decent chance a diagram already exists showing your assets grouped into zones, with the connections between them marked as conduits. That’s the model laid out in IEC 62443, the industrial cybersecurity standard most plants already reference to pass an audit. A zone is a group of assets that share common security requirements, in practice a shared trust level. A conduit is the controlled path connecting zones. The diagram usually gets drawn, signed off, and filed. Drawing it and enforcing it turn out to be two different projects, and most segmentation efforts stall in the space between them. Explain the threat, not the control or the standard. A rule that blocks a port, or a sentence about enabling microsegmentation, means nothing to someone running a line. A rule that stops a compromised sensor from reaching the equipment next to it means something. Lead with the second sentence every time, and let the standard stay in the audit paperwork where it belongs.Start small, but start. The segmentation projects that stall tend to share one thing: they were waiting for a complete asset inventory before writing a first rule. The ones that move usually skipped that step and started with whatever would hurt the business most if it went down. That’s a much shorter list, and someone in the room already knows what’s on it. Cut the obvious before building anything clever. Before writing an allow rule, block what has no legitimate reason to be on a plant network. The table below is a starting point, not an exhaustive list.Protocol / portWhy it’s riskyField severity (1–10)*SMB (Server Message Block), port 445The protocol EternalBlue used to spread WannaCry; still a common path for lateral movement10NetBIOS, ports 137–139Used for name resolution; easy to spoof9Microsoft RPC (Remote Procedure Call), port 135A common step in ransomware chains9LLMNR/NBNS, port 5355Can be abused to poison name resolution and capture credentials9Telnet / FTP, ports 23/21Older protocols that send credentials in plain text8TFTP (Trivial File Transfer Protocol), UDP port 69No authentication; can be abused to tamper with device firmware8RDP (Remote Desktop Protocol), port 3389A common remote-access entry point, often missing multi-factor authentication7*Severity ratings reflect internal field patterns, not an external benchmark.On the plant floor this isn’t just hygiene. Many operator stations and engineering workstations still running these protocols sit on older Windows builds that can’t be patched without a vendor-approved change window, sometimes not at all. For machines like that, blocking these at the network layer is often the only control available. Know your order of operations. Before writing a rule, know what level it lives at and which level wins when two rules disagree. Three levels show up in nearly every platform: global rules written once for the whole environment, template rules scoped to a region or device type, and site rules written for one location. The implementation differs across vendors, so confirm how yours resolves a conflict before you assume it matches another one you’ve used.IEC 62443 answers a related but different question. When two zones carry different target security levels, the conduit between them has to meet the stricter of the two. That’s about how tough the conduit’s rules need to be, not which rule fires first, and getting the two confused is how the wrong rule ends up quietly winning over the one meant to enforce the tougher standard.Visibility is the foundation. You can’t segment what you can’t see, and OT visibility is its own problem with its own constraints. I went deeper on the discovery challenge itself in the prior post; this one assumes you’ve got a source of truth and focuses on what to do with it.Establish that source of truth, asset visibility tooling, a CMDB, a deployed Zero Trust Branch, whatever your environment already trusts. Once you have it, you need a way to label what’s in it. I’ve seen customers use the native tags that come with their visibility tools. For instance, some write policy based on model number, Purdue level, or even the network the asset sits on. I’ve also seen customers apply their own custom labels after discovery, so the taxonomy fits their specific environment instead of whatever the tool shipped with.Whatever labeling you land on, use it to answer the questions that actually drive policy: which assets are critical to the business, which run end-of-life software nobody can patch, and which are both valuable and exposed at once. That last group is the one people miss. It’s easy to flag an unpatched low-value device or a current high-value one; the overlap is harder to catch, and it’s where the first rules should go.Map how things actually talk before deciding how they’re allowed to talk. This step gets skipped because it feels slow, and it is slow. Depending on the tooling, mapping every real flow on a plant network can be a tedious, manual slog. Zero Trust Branch makes this easier by surfacing the flows for you rather than making you reconstruct them by hand. I’ll go deeper on how in a follow-up post. For now, try to map these flows for your critical assets at least. Broad ports are fine at this stage. The goal is not breaking anything on the first pass, not precision. You can iterate and tighten later.Protect the crown jewels, and keep the whitelist scoped. This is where discipline tends to slip. Teams identify their critical assets correctly, then write a rule broad enough to recreate the same exposure they were trying to close, just at a smaller scale.Scoped doesn’t mean minimal. It means every rule, even the ones applied everywhere, names a destination and a reason. A small set of infrastructure rules tends to show up at the global layer before any site-specific policy gets written: a vulnerability scanner reaching defined targets and ports instead of every port on every host, a security agent’s callback scoped to that vendor’s cloud destination and nothing else, a cloud inspection service scoped to its own destination, DNS and time services pointed at internal resolvers and time sources rather than the open internet, and domain controller authentication written as two separate flows, client-to-DC and DC-to-DC, instead of one symmetric rule.Moving past infra, every plant also has a short list of applications that run the business itself, and those deserve the same explicit treatment. Maybe it’s a historian polling controllers for process data. Maybe it’s an MES talking to line controllers, or a SCADA system polling remote terminal units. Whatever the application, name the asset, name the destination, name the protocol. Beyond zones and conduits. In zone-and-conduit terms, the critical asset group is the zone, and the scoped rule protecting it is the conduit. Getting from a flat network to zones and conduits is still a real win over where most plants started. The question worth asking is whether it’s enough.IEC 62443 governs what crosses a zone boundary. It says nothing about what happens between two devices that already share one, and that’s usually where lateral movement happens once an attacker gets a foothold. Treating the zone as the unit of trust made sense when the alternative was a flat network. It doesn’t hold up against an attacker who only needs one opening and a clear path to the next device.We think OT security is heading past the zone as the unit of trust, toward the device. The question shifts from which zone a device belongs to, toward whether it has any legitimate reason to talk to the device next to it. A compromised sensor shouldn’t reach the PLC three feet away just because they share a segment. The standard sets the floor: zones and conduits. Where we see things heading is past it: every device as its own enforcement boundary, every connection justified on its own terms. Observe before you enforce. Run new rules in a logged, non-blocking state first, and watch what still hits the old broad rule. In information technology, a bad rule means a ticket and a rollback. In OT, it can mean a stopped line or a safety system doing something nobody predicted, with no quick fix available mid-shift. This step decides whether a program survives contact with production or gets shut off after the first outage.Iterate. Segmentation isn’t a project with an end date. Correlate signals across sources over time, retire rules that haven’t fired in months, and expect policy to drift as the environment changes.Wherever you’re starting from, zones and conduits on a whiteboard or a network that’s still flat, the move is the same: block the known bad, pick the handful of assets that would hurt the most if they went down, and write the first scoped rule around them. Everything else can wait.None of this requires waiting for a perfect inventory or a finished diagram. It requires picking a place to start and starting.
[#item_full_content] A few months back I wrote about why the factory floor feels unsecurable: uptime pressure that deprioritizes security, equipment that can’t be patched on a normal schedule, and networks flat enough that one compromised sensor can reach almost anything else on them (Securing the Unsecurable: OT, IoT, and the Factory Floor)). The most common question back was some version of: okay, so how do we actually do this?Before the how, here are the principles. They hold regardless of what’s enforcing them.If you’ve sat through a plant security review recently, there’s a decent chance a diagram already exists showing your assets grouped into zones, with the connections between them marked as conduits. That’s the model laid out in IEC 62443, the industrial cybersecurity standard most plants already reference to pass an audit. A zone is a group of assets that share common security requirements, in practice a shared trust level. A conduit is the controlled path connecting zones. The diagram usually gets drawn, signed off, and filed. Drawing it and enforcing it turn out to be two different projects, and most segmentation efforts stall in the space between them. Explain the threat, not the control or the standard. A rule that blocks a port, or a sentence about enabling microsegmentation, means nothing to someone running a line. A rule that stops a compromised sensor from reaching the equipment next to it means something. Lead with the second sentence every time, and let the standard stay in the audit paperwork where it belongs.Start small, but start. The segmentation projects that stall tend to share one thing: they were waiting for a complete asset inventory before writing a first rule. The ones that move usually skipped that step and started with whatever would hurt the business most if it went down. That’s a much shorter list, and someone in the room already knows what’s on it. Cut the obvious before building anything clever. Before writing an allow rule, block what has no legitimate reason to be on a plant network. The table below is a starting point, not an exhaustive list.Protocol / portWhy it’s riskyField severity (1–10)*SMB (Server Message Block), port 445The protocol EternalBlue used to spread WannaCry; still a common path for lateral movement10NetBIOS, ports 137–139Used for name resolution; easy to spoof9Microsoft RPC (Remote Procedure Call), port 135A common step in ransomware chains9LLMNR/NBNS, port 5355Can be abused to poison name resolution and capture credentials9Telnet / FTP, ports 23/21Older protocols that send credentials in plain text8TFTP (Trivial File Transfer Protocol), UDP port 69No authentication; can be abused to tamper with device firmware8RDP (Remote Desktop Protocol), port 3389A common remote-access entry point, often missing multi-factor authentication7*Severity ratings reflect internal field patterns, not an external benchmark.On the plant floor this isn’t just hygiene. Many operator stations and engineering workstations still running these protocols sit on older Windows builds that can’t be patched without a vendor-approved change window, sometimes not at all. For machines like that, blocking these at the network layer is often the only control available. Know your order of operations. Before writing a rule, know what level it lives at and which level wins when two rules disagree. Three levels show up in nearly every platform: global rules written once for the whole environment, template rules scoped to a region or device type, and site rules written for one location. The implementation differs across vendors, so confirm how yours resolves a conflict before you assume it matches another one you’ve used.IEC 62443 answers a related but different question. When two zones carry different target security levels, the conduit between them has to meet the stricter of the two. That’s about how tough the conduit’s rules need to be, not which rule fires first, and getting the two confused is how the wrong rule ends up quietly winning over the one meant to enforce the tougher standard.Visibility is the foundation. You can’t segment what you can’t see, and OT visibility is its own problem with its own constraints. I went deeper on the discovery challenge itself in the prior post; this one assumes you’ve got a source of truth and focuses on what to do with it.Establish that source of truth, asset visibility tooling, a CMDB, a deployed Zero Trust Branch, whatever your environment already trusts. Once you have it, you need a way to label what’s in it. I’ve seen customers use the native tags that come with their visibility tools. For instance, some write policy based on model number, Purdue level, or even the network the asset sits on. I’ve also seen customers apply their own custom labels after discovery, so the taxonomy fits their specific environment instead of whatever the tool shipped with.Whatever labeling you land on, use it to answer the questions that actually drive policy: which assets are critical to the business, which run end-of-life software nobody can patch, and which are both valuable and exposed at once. That last group is the one people miss. It’s easy to flag an unpatched low-value device or a current high-value one; the overlap is harder to catch, and it’s where the first rules should go.Map how things actually talk before deciding how they’re allowed to talk. This step gets skipped because it feels slow, and it is slow. Depending on the tooling, mapping every real flow on a plant network can be a tedious, manual slog. Zero Trust Branch makes this easier by surfacing the flows for you rather than making you reconstruct them by hand. I’ll go deeper on how in a follow-up post. For now, try to map these flows for your critical assets at least. Broad ports are fine at this stage. The goal is not breaking anything on the first pass, not precision. You can iterate and tighten later.Protect the crown jewels, and keep the whitelist scoped. This is where discipline tends to slip. Teams identify their critical assets correctly, then write a rule broad enough to recreate the same exposure they were trying to close, just at a smaller scale.Scoped doesn’t mean minimal. It means every rule, even the ones applied everywhere, names a destination and a reason. A small set of infrastructure rules tends to show up at the global layer before any site-specific policy gets written: a vulnerability scanner reaching defined targets and ports instead of every port on every host, a security agent’s callback scoped to that vendor’s cloud destination and nothing else, a cloud inspection service scoped to its own destination, DNS and time services pointed at internal resolvers and time sources rather than the open internet, and domain controller authentication written as two separate flows, client-to-DC and DC-to-DC, instead of one symmetric rule.Moving past infra, every plant also has a short list of applications that run the business itself, and those deserve the same explicit treatment. Maybe it’s a historian polling controllers for process data. Maybe it’s an MES talking to line controllers, or a SCADA system polling remote terminal units. Whatever the application, name the asset, name the destination, name the protocol. Beyond zones and conduits. In zone-and-conduit terms, the critical asset group is the zone, and the scoped rule protecting it is the conduit. Getting from a flat network to zones and conduits is still a real win over where most plants started. The question worth asking is whether it’s enough.IEC 62443 governs what crosses a zone boundary. It says nothing about what happens between two devices that already share one, and that’s usually where lateral movement happens once an attacker gets a foothold. Treating the zone as the unit of trust made sense when the alternative was a flat network. It doesn’t hold up against an attacker who only needs one opening and a clear path to the next device.We think OT security is heading past the zone as the unit of trust, toward the device. The question shifts from which zone a device belongs to, toward whether it has any legitimate reason to talk to the device next to it. A compromised sensor shouldn’t reach the PLC three feet away just because they share a segment. The standard sets the floor: zones and conduits. Where we see things heading is past it: every device as its own enforcement boundary, every connection justified on its own terms. Observe before you enforce. Run new rules in a logged, non-blocking state first, and watch what still hits the old broad rule. In information technology, a bad rule means a ticket and a rollback. In OT, it can mean a stopped line or a safety system doing something nobody predicted, with no quick fix available mid-shift. This step decides whether a program survives contact with production or gets shut off after the first outage.Iterate. Segmentation isn’t a project with an end date. Correlate signals across sources over time, retire rules that haven’t fired in months, and expect policy to drift as the environment changes.Wherever you’re starting from, zones and conduits on a whiteboard or a network that’s still flat, the move is the same: block the known bad, pick the handful of assets that would hurt the most if they went down, and write the first scoped rule around them. Everything else can wait.None of this requires waiting for a perfect inventory or a finished diagram. It requires picking a place to start and starting.